IoT sensor

Stop condensation before it starts.

Continuous humidity sensing, room to rack.

Continuous humidity monitoring for data centers and critical facilities, preventing condensation damage and keeping conditions within safe limits.

  • Relative humidity
  • Condensation risk
  • Room & rack
  • Real-time
Humidity sensor
Prochista relative humidity sensor

What it monitors

Humidity, rack to room.

Relative humidity

Continuous relative humidity across rooms, aisles and racks.

Condensation risk

Catch dew-point conditions before condensation can form.

Safe envelope

Keep humidity inside the range your equipment needs.

Deployed acrossData centersTelecom sheltersCritical facilities

Humidity sensor datasheet

Full specifications, dimensions and wiring, in one PDF.

Built for the field

Purpose-built for harsh, critical sites.

Industrial-grade hardware that survives the conditions of real data-center, telecom and utility sites.

Wide operating range

Rated for the temperature and humidity extremes of unmanned sites.

Rack & room coverage

Spot, rack-level and room-level placement from one sensor family.

Real-time readings

Continuous measurement streamed straight to the platform.

Configurable alerts

Per-sensor thresholds that fire before limits are breached.

Open protocols

SNMP, Modbus, BACnet, MQTT and Redfish, with no proprietary lock-in.

ProDCIM-native

Plug-and-play into ProDCIM dashboards and the 3D model.

Open protocols

Connect over any open protocol you run.

No proprietary lock-in. Prochista monitors over the open industrial and IT protocols your equipment, servers and BMS already speak, so it drops into the systems you have today and streams straight to the platform.

SNMP

IT & network

v1 / v2c / v3 + traps from network and power gear

Redfish

IT & network

Modern REST/JSON server & hardware telemetry

Modbus RTU

Industrial / OT

Serial RS-485 field devices and meters

Modbus TCP

Industrial / OT

Ethernet Modbus for PLCs, meters and gateways

BACnet

Building / BMS

Building-management, HVAC and cooling systems

MQTT

IoT & messaging

Lightweight pub/sub for IoT and edge telemetry

REST API

APIs & integration

Open HTTP API to pull or push readings

Webhooks

APIs & integration

Event push into ticketing, chat and automation

+ your protocol

Custom and legacy integrations on request.

Open standards, with no proprietary lock-in.

From the rack to the dashboard

A reading, not just a sensor.

Sensors only matter if their data reaches the right people in time. Each reading is acquired at the edge and delivered straight to ProDCIM.

SensorLIVE

Continuous readings, monitored live, illustrative

Prochista relative humidity sensor
Humidity sensor
Prochista data-acquisition nodeAcquire · normalize
prodcim.local · monitoring
Sensor readings in the ProDCIM platform

Sample platform data shown

1. Place

Mount the sensor at rack, row or room level.

2. Measure

Readings are sampled continuously at the edge.

3. Detect

Threshold and anomaly logic flag issues as they emerge.

4. Alert

The right team is notified, with the location attached.

Explore at your own pace

Not ready for a demo? Take the next step.

Plan your deployment

Answer a few questions and get a recommended deployment profile in about a minute.

Open the planner

See humidity monitoring on your sites

Book a walkthrough and we'll map your sensors, racks and sites into one monitoring platform.